Voyage : | 2002/03 V7 - Link to additional Voyage details | |||||||||
Vessel : | Polar Bird | |||||||||
Duration : | 22-Feb-2003 to 14-Mar-2003 UTC | |||||||||
Spatial Bounds : |
| |||||||||
Voyage Leader : | Martin Betts |
Sensor | Details |
---|---|
Instrument Anemometer |
Serial No : Polarbird RM Young annemometer 99/00 > Location : Mast Accuracy : Wind Speed +/- ??? m/s Wind Direction +/- 3 degrees Resolution : Wind Speed - 0.1m/s Wind Direction - 0.1 degrees Output : Wind Speed is AC frequency where 1 knot=0.1904Hz Wind Direction is resistance where 10kohms = 355 degrees Usually interfaced to system via RM Young 05603 interface which provides 0-5V ouputs. Notes : Range 0 to 60m/s Threshold sensitivity 1.0 m/s |
Instrument Barometer |
Serial No : PTB220_V3730001 PB Location : Instrumentation box Accuracy : Resolution : Output : Notes : |
Instrument Datataker |
Serial No : DT600_31563 # 36448 (PCMCIA) Location : Instrumentation box Accuracy : Analog input accuracy 0.15% of full scale Resolution : 15 bits plus sign, 1uV Output : ASCII Serial Data RS232 at 4800 baud (N,8,1) Notes : |
Instrument GPS |
Serial No : GPS112_KD82445_PB Location : Mast Accuracy : Position 2D RMS (PDOP <3), 100m with SA Resolution : Output : NMEA RS232 data @ 4800 baud (n,8,1) Notes : |
Instrument Humidity |
Serial No : HMP233_X0520019 PB Location : Port Accuracy : Resolution : Output : ASCII Serial Data RS232 at 4800 baud (E,7,2) Notes : |
Instrument Humidity |
Serial No : HMP233_X0520018 PB Location : Stbd Accuracy : Resolution : Output : ASCII Serial Data RS232 at 4800 baud (E,7,2) Notes : |
Instrument Radiation - Solar |
Serial No : EP08_8410 Location : Port Accuracy : +/-3% Resolution : analogue output - limited by measuring equipment Output : typically 5 to 7 uV/W.m^-2 Notes : Viewing angle 2 pi sr irradiance 0 - 1400 W.m^-2 response time < 40s @99%, <24s @95%, <9s @63% non-stability <+/-1.5%/year non linearity <+/-1% at 500W/m2 tilt response < +/-2% at 1000 W/m2 operating temperature -20 to +60C temperature response <2% deviation for 50K interval cosine error <+/-5% of ideal |
Instrument Radiation - Solar |
Serial No : EP08_8411 Location : Stbd Accuracy : +/-3% Resolution : analogue output - limited by measuring equipment Output : typically 5 to 7 uV/W.m^-2 Notes : Viewing angle 2 pi sr irradiance 0 - 1400 W.m^-2 response time < 40s @99%, <24s @95%, <9s @63% non-stability <+/-1.5%/year non linearity <+/-1% at 500W/m2 tilt response < +/-2% at 1000 W/m2 operating temperature -20 to +60C temperature response <2% deviation for 50K interval cosine error <+/-5% of ideal |
IT Terminal Server |
Serial No : ETS-8P_00-80-A3-17-24-F6_PB Location : Instrumentation box Accuracy : Resolution : Output : TCP\IP, RS232C serial Notes : |